Our compact body (85mm) true condenser type with integrated capsule and amplifier is available in two models the MBNM 440 cardioid and the MBNM 410 omni. Using advanced SMD technology with an extremely short signal path and low phantom power consumption plus the ability to accept voltages from 22 to 48 V, these microphones are well suited for battery operation. With a non-reflective lacquered mat black housing, precise and stunning sound reproduction is available at an entry-level price.
What you are looking at is not an extraterrestrial spa-cecraft but a "Schneider disc". The Schneider disc is a variation of the Jecklin disc developed by Jürgen Jeck-lin for his stereo microphone technique known as Opti-mal Stereo Signal (OSS). The idea behind OSS is to use a pair of spaced omnidirectional microphones approximately 6 inches apart (roughly the distance bet-ween the human ears) with a disc placed in between the spaced pair. The disc is covered with a thin layer of foam intended to absorb high frequencies - thus impro-ving stereo separation between the microphones. The difference between the two types of discs is the foam sphere at the center of the Schneider disc, which redu-ces the amount of high-frequency energy reflected from the disc, and results in an increase of stereo separation.Below approximately 200 Hz, the Schneider disc has little (if any) effect on the stereo signal because the audio wavelength is large enough to bend around thedisc, equally reaching both microphones. However as frequency increases above 200 Hz, the Schneider disc's foam sphere increases stereo separation between the spaced pair.
omni pattern - features 6 dB peak at 8-9 kHz for more distant pickup - recommended for outdoor recordings if less directivity is desired - frequency response 10 - 20.000 HKA 100 DK
recommended preamp MBP 603 (A) MBP 680 MBP 648 (A)
frequency response Hz 10 - 20.000 10 - 20.000 10 - 20.000
sensivity 12 mV/Pa 6 mV/Pa 6 mV/Pa
signal to noise ratio CCIR 68 dB 62 dB 67 dB
equivalent SPL rated at CCIR 26 dB 32 dB 27 dB
signal to noise ratio DIN/ IEC 80 dB 75 dB 80 dB
equivalent SPL rated at DIN / IEC 14 dB 19 dB 14 dB
max. spl 132 dB 132 dB 132 dB
size ø 21 x 20 m
A constant frequency response if the sound impinges frontally upon the capsule. This leads to a natural tonal response. With a non-axis impingement of sound upon the microphone, a decay of treble results. This effect is relevant when sound quotas come from other angles than 0°, for instance by reflectionsKA 100 LK
recommended preamp MBP 603 (A) MBP 680 MBP 648 (A)
frequency response Hz 10 - 20.000 10 - 20.000 10 - 20.000
sensivity 12 mV/Pa 6 mV/Pa 6 mV/Pa
signal to noise ratio CCIR 68 dB 62 dB 67 dB
equivalent SPL rated at CCIR 26 dB 32 dB 27 dB
signal to noise ratio DIN/ IEC 80 dB 75 dB 80 dB
equivalent SPL rated at DIN / IEC 14 dB 19 dB 14 dB
max. spl 132 dB 132 dB 132 dB
size ø 21 x 20 mm
Our large diaphragm capsule with cardioid characteristic is an ideal solution for recording of singers, choirs,piano, saxophone and guitar. The pleasing warm sound has a fine-drawing, nice and airy effect. The vintage capsule design features gold sputtered membran and brass back platspecificationsKA 1000 N
recommended preamp MBP 603 (A) MBP 648 (A)
frequency response 10 - 20.000 Hz 10 - 20.000 Hz
sensitivity 11 mV/Pa 11 mV/Pa
signal to noise ratio CCIR 67 dB 67 dB
equivalent SPL rated at CCIR 27 dB 27 dB
signal to noise ratio DIN/IEC 79 dB 79 dB
equivalent SPL rated at DIN/IEC 15 dB 15 dB
max. spl 132 dB 132 dB
size ø 50 x 20 m
The 35 mm double-diaphragm system with gold sputtered polyester foil 6 µm is manufactured with precision and tolerances in the µ-range. Recordings sound particularly preciseKA 1100 K
recommended preamp MBP 603 (A) MBP 648 (A)
frequency response 5 - 20.000 Hz 5 - 20.000 Hz
sensitivity 11 mV/Pa 11 mV/Pa
signal to noise ratio CCIR 67 dB 67 dB
equivalent SPL rated at CCIR 27 dB 27 dB
signal to noise ratio DIN/IEC 79 dB 79 dB
equivalent SPL rated at DIN/IEC 15 dB 15 dB
max. s
cardioid pattern - highly versatile capsule - maximum rejection on rear-incident sound - X/Y recordings or Mid-Side configuration - frequency response 40 - 20.000 Hz - neutral record space + 135KA 200 N cardioid
recommended preamp MBP 603 (A) MBP 680 MBP 648 (A)
frequency response Hz 40 - 20.000 40 - 20.000 40 - 20.000
sensitivity 14 mV/Pa 7 mV/Pa 7 mV/Pa
signal to noise ratio CCIR 69 dB 63 dB 68 dB
equivalent SPL rated at CCIR 25 dB 31 dB 26 dB
signal to noise ratio DIN / IEC 82 dB 76 dB 81 dB
equivalent SPL rated at DIN / IEC 12 dB 18 dB 13 dB
max. spl 130 dB 130 dB 130 dB
size ø 21 x 20 m
wide cardioid pattern - slight increase in low-frequency reproduction (compared to KA 200) - frequency response 20 - 20.000 HzKA 300 NB
recommended preamp MBP 603 (A) MBP 680 MBP 648 (A)
frequency response Hz 20 - 20.000 20 - 20.000 20 - 20.000
sensitivity 12 mV/Pa 6 mV/Pa 6 mV/Pa
signal to noise ratio CCIR 68 dB 62 dB 67 dB
equivalent SPL rated at CCIR 26 dB 32 dB 27 dB
signal to noise ratio at DIN / IEC 80 dB 75 dB 80 dB
equivalent SPL rated at DIN / IEC 14 dB 19 dB 14 dB
max. SPL 130 dB 130 dB 130 dB
size ø 21 x 20 m
cardioid speech optimized - 12 dB low cut at 50 Hz - frequency response 50 - 20.000 HzKA 400 N cardioid
recommended preamp MBP 603 (A) MBP 680 MBP 648 (A)
frequency response Hz 50 - 20.000 50 - 20.000 50 - 20.000
sensitivity 15 mV/Pa 7 mV/Pa 7 mV/Pa
signal to noise ratio CCIR 70 dB 63 dB 68 dB
equivalent SPL rated at CCIR 24 dB 31 dB 26 dB
signal to noise ratio DIN / IEC 83 dB 76 dB 81 dB
equivalent SPL rated at DIN / IEC 11 dB 18 dB 13 dB
max. SPL 131 dB 131 dB 131 dB
size ø 21 x 20 m
The MBNM 150 EN represents the sum total of exhaustive research into just what would repres the îperfect electret podium microphoneî. The elect cardioid capsule is mounted on a fully adjustable g seneck. The 12 mm fixed capsule has extraordina well off axis rejection with built in compensation for proximity effect. Sleek industrial design with a g Nextel finish make the microphone seems as visu transparent as it sounds! While an XLR serves as output connector, the microphone can shipped wit 3/8î threaded sleeve with a lateral outlet and a 3 cable to the preamp. Awide voltage range is acco modated with extremely stable operating results.specifications
directional characteristic cardioid
sound source direction axial
phantom power / feed current 48 V / ca. 1,7 mA
frequency response 80 - 20.000 Hz
sensitivity of field idling 1,0 mV/µbar
at 1 k? -1 kHz 10 mV/Pa
signal to noise ratio rated at 1 Pa. CCIR 61 dB
signal to noise ratio rated at CCIR 33 dB
equivalent SPLrated at DIN / IEC 73 dB-A
equivalent SPLrated at CCIR 21 dB-A
max. spl at 1 k? 130 dB
electrical impedance 200 ?
connector XLR / 3/8ì
size / weight ¯ 12 /19 x 350 mm / 160 g